HomeAirport Technical Information

ATIS CONTACT NUMBER: + 353 1 5241219

EIWT Obstacle Data - Email: ops@westonairport.com

Runway Data

(VOR based instrument approach on runway 25, pending IAA approval)
Length 924m 924m
TORA (m) 924m x 23m 924m x 23m
TODA (m) 924m x 23m 1381m
ASDA (m) 924m x 23m 1381m
LDA (m) 924m x 23m 924m
weston-airport-runway
business-aviation-color

Air Traffic Control

Dublin Weston Airport is in Class “C” airspace, known as the “Weston Area of Responsibility” or AOR. During published opening hours, an Air Traffic Control Service is provided, (Freq 122.4), call sign “Weston Tower”.

Instructions and clearances are issued in accordance with Rule 27 of S.I. No: 72/2004 (Rules of the Air). Pilots are reminded, on first contact, to listen first before transmitting as the frequency can be busy especially at weekends during summer time.

business-aviation-color

Circuit Procedure

A left circuit off RWY 25, or a right circuit of RWY 07, result in a penetration of the EIR15 (encroaching on the ILS Approach to runway 11 at Baldonnel). As these are the preferred directions for circuits to both runways, an agreement exists between Weston ATS and Baldonnel ATS for same.

These circuits are based on the premise that Weston aircraft will remain North of the railway line at all times. At all other times at Weston, circuits off runway 25 shall be right-hand and circuits off runway 07 shall be left-hand. Due to the nature of Baldonnel operations, pilots engaged in circuits at Weston should be prepared for changes to the circuit direction at short notice from Weston ATS.

business-aviation-color

Runway 25 Left Circuit

After take-off and established in a positive climb, a gentle RIGHT turn to over fly the reservoir climbing to 1000ft QNH.
Avoid any helicopter activity in the Heli-Training Area beside the VOR on your right.

On reaching 1000ft QNH, turn left onto the crosswind leg and continue the turn onto the downwind leg making sure you are north of the railway line at all times. Turn left onto base when abeam the Spa Hotel remaining clear of Lucan village.
Establish finals no lower than 650ft QNH.

business-aviation-color

VFR Arrival Routes (Standard)

From the West: Call Weston ATS five miles or five minutes before the AOR boundary then, once cleared to do so, route North of Maynooth towards Leixlip at 1500ft QNH. When abeam the Intel industrial complex, make a right turn towards the airfield to arrive overhead at 1500ft QNH. Report overhead at 1500ft QNH and join the circuit pattern giving way to circuit traffic.

From the East: When handed over from Dublin ATS to Weston ATS, once cleared to do so, route along the N4 or River Liffey to arrive overhead the airfield at 1500ft. Report overhead at 1500ft QNH and join the circuit pattern giving way to circuit traffic.

events

Locations & Data

ICAO Code
EIWT

Lat/Long
532108N – 0062918W

Eircode
Dublin, W23 XHF8

Elevation
155ft

Runway 07/25
924m

Fire Category
CAT3
CAT4  - Available PPR

Taxiways

A/B/C/D/E/F/G/H/J/K
PCN45/F/A/W/T

Main Apron
PCN45/F/A/W/T

  1. Pilots must ensure that they do not penetrate the R15 and R16 without advance clearance from the Baldonnnel ATC, or the Dublin CTA / CTR, without advance clearance from Dublin ATC.
  2. Pilots are requested to avoid over flying the Technology Campus and Industrial Complex located close to the field.
  3. Filing of Flight Plans is solely the responsibility of the aircraft operator.

Flying Into Dublin Weston Airport